|
|
|
|
¡¡ Control panel: |
|
|
|
|
|
¡¡Wireless door
magnet: |
|
|
|
|
|
¡¡Wireless motion
detector: |
|
|
|
|
|
|
|
|
|
¡¡Wireless keyfob:
|
|
|
|
¡¡Wireless-hardwire
signal translator: |
|
|
|
¡¡Wireless siren:
|
|
|
|
¡¡Wireless repeater:
|
|
|
|
¡¡Hardwire infrared
motion detector: |
|
|
|
|
|
¡¡Hardwire control
and keypad: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Control panel: R75-V (voice reporting) |
R75 series are advanced models among the control panels of wireless home security systems. With more functions, R75 series satisfy user's needs by integrating latest wireless and information technology. The difference between R75-V and R75-N is their reporting modes ¨C report to the monitoring center or to the user telephones. When an alarm occurs, R75-V dials the telephone/cell phone numbers preset by the user, and sends voice alarm messages.
The illustration is as following:
The R75 is the control and indicating equipment (CIE) of the wireless security system.
Working together with various detectors, the R75 provides the following protections:
Intrusion protection (with motion detectors, door/window magnet contacts)
Fire protection (with smoke detectors)
Gas protection (with gas detectors)
Emergency protection (with emergency buttons)
Meanwhile, R75 also provides the following additional functions:
Tamper detection (detection of illegally opening the covers)
Password attempting prevention
Fault detection (detection of power fault, battery low-power, telephone line cut)
Supervising the wireless detectors, buttons, and sirens.
Remote controlling (keyfob and remote access by telephone(R75-V only))
Event recording User management (add/delete users)
Integrated in R75-V: ¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡control, indicating equipment, ¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡80x50mm blue LCD, ¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡color membrane switch keypad as user input interface, ¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡color LED as instruction, ¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡back-up battery, ¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡alarm transmission equipment, ¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡mic and speaker, ¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡storage device. Operation mode: 3 modes. Stay, Away, and Disarm. Zones:¡¡¡¡¡¡¡¡¡¡¡¡ 19 burglar-proof zones, up to 95 wireless detectors ¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡ 1 fire detection zone, up to 5 wireless detectors ¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡ 1 hazardous gas detection zone, up to 5 wireless detectors ¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡ 1 24-hour zone, up to 5 wireless detectors
1 emergency zone, up to 5 wireless emergency buttons
¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡ 1 siren zone, up to 2 wireless sirens
Wireless frequency:¡¡ 868Mhz/915Mhz FSK. 2-way wireless
User number:¡¡¡¡ ¡¡up to 9 different users ¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡ up to 9 wireless keys Event record:¡¡¡¡ ¡¡alarm record, fault record, arm/disarm record, and data change record ¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡ Total 125 pieces
Notice: fault notices, and new alarm notices Personal setting: 8 private telephone/mobile numbers, 2-way voice volume, remote telephone operation, entry/exit delay times¡ total 26 adjustable parameters Operation instruction: LCD Access level management: 2 levels
Standard:¡¡¡¡¡¡¡¡ DD CLC/TS 50131-3: 2003 ¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡ EN50131-5-3: 2005 Security grade:¡¡ 2 Environmental class: 1(Indoor) Power input:¡¡ 9VAC 50/60Hz 500mA
Dimension:¡¡¡¡¡¡ 244x167x45 (mm)
Weight: 620g(with batteries), 530g(without batteries)
Operating temperature range: 10¡æ- 40¡æ Maximum current consumption (with an alarm condition, inside siren sounding): 210mA Quiescent current consumption (without an alarm condition): 95mA
Technical Features
A: Wireless and Easy to install All detectors, contacts, and hold-up buttons are wireless. Users can enroll new devices, delete any existing one, or move the devices to a new place easily. Just following the Guide, users can install the system by themselves, and set R75-V to meet their needs. If a device does not work well, R75-V will give detailed message automatically, thus the maintenance becomes very easy.
B: Two-way voice, and real location in voice R75-V calls the telephone numbers preset by users when there comes an alarm. Listeners can acquire the following alarm information: Whose home it is (pre-recorded by user), what kind alarm it is (an emergency call? a burglar alarm? or other reasons?), how many zones the intruder has passed, and the zone numbers (only for burglar) or the real location (for example, 1st floor kitchen). Listeners can follow voice instruction to take following operations: Confirm the alarm, disarm the security system, monitor, talk with the intruder, stop siren, or start siren. Using these functions, users may evaluate the circumstance, and then take proper actions.
C: Use the system anywhere by just making a call Users can operate their systems by local keypad, wireless keys, or by just making a call to home. R75-V answers incoming calls automatically if no one is at home. Following the voice instruction, callers can set system 'arm', or set 'disarm' (password required). If someone tries your passwords, R75-V will send an 'invalid password attemption' alarm.
|
|
|